Resultado da pesquisa (2)

Termo utilizado na pesquisa Ferreira M.I.C.

#1 - Absolute lymphocyte counts and antibodies against enzootic bovine leukosis virus in dairy herds of Rio de Janeiro

Abstract in English:

Fifty-five dairy cows from two herds located in the State of Rio de Janeiro, were evaluated monthly over a six month period for persistent lymphocytosis (PL) and for the presence of plasma antibody to the major glycoprotein (gp51) of bovine leukosis virus (BLV), as evidence of infection. Absolute lymphocyte counts were superimposed on Bendixen's hematological key for bovine leukosis. Animals were considered to have PL when, during the six month period, three absolute lymphocyte counts were above 7000 per mm3 of blood. In herd A, of 15 absolute lymphocyte counts from three antibody-negative cows, 13 (86.7%) were normal and two (13.3%) suspect. Counts from 17 antibody-positive cows from the sarne herd showed 29 (30.5%) normal, 36 (37.9%) suspect and 30 (31.6%) leukotic. In herd B, of 82 absolute lymphocyte counts from 14 antibody-negative cows, 45 (54.9%) were normal, 23 (28.1%) suspect and 14 (17.0%) leukotic. Counts from 21 antibody-positive cows showed that 53 (45.3%) were normal, 40 (34.2%) were suspect and 24 (20.5%) were leukotic. It is concluded that PL is an unreliable criterion to identify cattle infected with BLV in the subtropical environment, and must not be used in programs aimed at controlling or eradicating BLV from infected herds. However, the hematological keys will continue to be useful in the diagnosis of the clinical disease, that is, the bovine lymphosarcoma. The use of the immunodiffusion test to detect antibody to gp51 in the plasma or serum of infected cattle is a simple and sensitive tool in the control of BLV infection.

Abstract in Portuguese:

Cinqüenta e cinco vacas leiteiras de dois rebanhos localizados no Estado do Rio de Janeiro foram examinadas mensalmente, durante um período de seis meses. para determinar a linfocitose persistente (LP) e a presença, no plasma, de anticorpos contra a glicoproteina maior (gp51) do vírus da leucose bovina (VLB), como evidência da infecção. As contagens linfocitárias absolutas foram sobrepostas à chave hematológica de Bendixen para leucose bovina. Os animais foram considerados portadores de LP quando, durante o período de seis meses, três contagens linfocitárias absolutas estavam acima de 7000 por mm3 de sangue. No rebanho A, de 15 contagens linfocitárias absolutas de três vacas anticorpo-negativas, 13 (86,7%) eram normais e duas (13,3%) atingiram a faixa de suspeitas. De 95 contagens de 17 vacas anticorpo-positivas do mesmo rebanho, ,29 mostraram-se (30,5%) normais, 36 (37,9%) suspeitas e 30 (31,6%) leucóticas. No rebanho B, de 82 contagens linfocitárias absolutas de 14 vacas anticorpo-negativas; 45 (54,9%) eram normais, 23 (28,1 %) suspeitas e 14 (17,0%) leucóticas. As 117 contagens de 21 vacas anticorpo-positivas mostraram que 53 (45,3%) eram normais, 40 (34,2%) eram suspeitas e 24 (20,5%) eram leucóticas. Concluiu-se que a LP é um critério pouco confiável na detecção de bovinos infectados com o VLB num ambiente subtropical e não deve ser utilizada em programas que objetivam a controlar ou erradicar o VLB de rebanhos infectados. Porém, as chaves hematológicas continuarão sendo úteis no diagnóstico da doença clínica, o linfossarcoma bovino. Ficou também evidente que a prova de imunodifusão para detectar anticorpos contra gp51 no plasma ou soro de animais infectados é um método simples e sensível para o controle da leucose bovina.


#2 - A comparative study between the plate and slide immunodiffusion tests in the detection of antibodies against enzootic bovine leukosis virus

Abstract in English:

The agar gel immunodiffusion tests performed in plates and on slides were compared in their efficiency to detect antibodies against the major glycoprotein gp51 of enzootic bovine leukosis virus (BLV). Materiais tested were milk, plasma and serum obtained from cattle belonging to seven dairy herds located in the States of Rio de Janeiro and São Paulo. Both tests were equally inefficient in the detection of antibodies in the milk. The plate immunodiffusion test was more sensitive than the slide test in the detection of antibodies in plasma, although, when the tests were performed with serum, both were equally sensitive in the identification of infected cattle. Out of a total of 1031 sera tested, 361 (35.0%) were identified as positive using the plate test, while the slide test detected 355 (34.4%) positives. It is concluded that- the slide inununodiffusion test can efficiently substitute for the plate immunodiffusion test in the detection of antibodies against gp51 of BLV in the serum, with the additional advantage of utilizing smaller amounts of glycoprotein antigen.

Abstract in Portuguese:

As provas de imunodifusão em ágar gel, realizadas em placa e em lâmina, foram comparadas quanto à eficiência em detectar anticorpos contra a glicoproteína maior gp51 rio vírus da leucose enzoótica bovina (VLB). As amostras testadas constaram de leite, plasma e soro, obtidos de bovinos pertencentes a sete rebanhos leiteiros dos Estados do Rio de Janeiro e São Paulo. Ambas as provas foram igualmente ineficientes na detecção de anticorpos no leite. A prova de imunodifusão em placa foi mais sensível que a prova em lâmina, na detecção de anticorpos no plasma, porém, quando as provas eram realizadas com soro, as duas eram igualmente sensíveis na identificação de bovinos infectados. De um total de 1031 soros testados, a prova em placa detectou 361 (35,0%) soros positivos enquanto a prova em lâmina 355 (34,4%). Concluiu-se que a prova em lâmina pode substituir a prova em placa eficientemente na detecção de anticorpos contra gp51 do VLB no soro, com a vantagem de utilizar menores quantidades de antígeno glicoprotéico.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV